ASR-9006-AC-Ref Overview
ASR-9006-AC is the Cisco ASR-9006 AC Chassis. Cisco ASR 9006 Router in a 10-rack unit (RU) form factor allows for a full featured, highly reliable deployment in space-constrained environments. This product comes fully equipped with all the same software functionality and line card options as the ASR 9010, just in a smaller package. With dual route switch processors (RSP) along with full commons redundancy, system and network resiliency become a reality for slot-reduced deployments. To provide ASR 9006 functions, ASR-9006-AC needs to be configured with necessary components separately.Quick spec of ASR-9006-AC-Ref
- Model : ASR-9006-AC
- Type : Cisco ASR-9006 AC Chassis
- ASR 9006 Specs :
- Slots : 4 Line Cards 2 RSPs
- Rack Size : 10 RU
- Max Capacity : 7 Tbps
- Size (H x W x D) : 17.5 in. x 17.5 in. x 28.65 in.
- Power : AC: 3 kW power module DC: 1.5 kW or 2.1 kW power modules Note: Mixing of AC and DC modules is not supported
- Fan : 2 fan trays
- Airflow : Side to Side (Front to Back Option)
- RSP / RP : 2 (1+1 RSP redundancy)
- Fabric Architecture : 1+1 fabric redundancy
- Software : IOS XR
ASR-9006-AC-Ref Specification
- Description :Cisco ASR 9006 Chassis, ASR-9006-AC, ASR-9006 AC Chassis
- Physical specifications :Height: 17.50 in. (444.5 mm) (10 RU) Width: 17.38 in. (441.45 mm) Depth: · With doors: 29.05 in. (737.9 mm) · Without doors: 29.05 in. (737.9 mm) Weight: · 89.55 lb (40.7 kg) (chassis with PEM) 150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) – RSP, two v2 FAN trays, PEMs
- Slot orientation :Horizontal
- Cisco ASR 9000 Series RSP :Dual redundant RSPs with integrated fabric in 2 slots
- Cisco ASR 9000 Series line cards :4 line-card slots
- “Commons” components :2 RSPs 2 fan trays 1 PEM (either DC or AC) 1 fan filter
- Reliability and availability :Fabric redundancy Fan redundancy Feed redundancy Power-supply redundancy RSP redundancy Software redundancy
- Rack mounting :19-in. default 21- and 23-in. adapters available Note: Minimum 17.75-in. opening between posts is needed for proper operation
- Cabinet mounting :Yes Note: Doors not recommended in enclosed cabinets
- Wall mounting :No
- Airflow :Right-to-back, Front-to-back with baffle
- Fabric :One per RSP: · Active/active nonblocking operation mode in dual-RSP redundant configuration · Fully redundant in dual-RSP redundant configuration · Built-in service-intelligence and traffic-prioritization capability
- Thermal :Two fan trays: · 6 high-efficiency fans per tray · Variable-speed fans for optimal thermal performance · No single point of failure
- Modularity :Pay-as-you-grow power for future scalability, available in AC and DC. Multiple power module types: · 3 kW AC power module · 2.1 kW DC power module Note: Mixing of AC and DC modules is not supported
- Redundancy :· AC: N+N redundancy · DC: N+1 redundancy · Power module redundancy · A/B Feed redundancy
- Power zones :No power zone restrictions Fully load-sharing power infrastructure
- Power input :Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum) Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
- Power-module airflow :Front-to-back
- Operating temperature (nominal) :41 to 104ºF (5 to 40ºC)
- Operating temperature (short-term) :ASR 9006: 23 to 131ºF (-5 to 55ºC) ASR 9010: 23 to 122ºF (-5 to 50ºC)
- Operating humidity (nominal) (relative humidity) :5 to 90%
- Storage temperature :-40 to 158ºF (-40 to 70ºC)
- Storage (relative humidity) :5 to 93%
- Operating altitude :-60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
- Network Equipment Building Standards (NEBS) :Cisco ASR 9006 is designed to meet: · SR-3580: NEBS Criteria Levels (Level 3) · GR-1089-CORE: NEBS EMC and Safety · GR-63-CORE: NEBS Physical Protection · VZ.TPR.9205: Verizon TEEER
- ETSI standards :Cisco ASR 9006 is designed to meet: · EN300 386: Telecommunications Network Equipment (EMC) · ETSI 300 019 Storage Class 1.1 · ETSI 300 019 Transportation Class 2.3 · ETSI 300 019 Stationary Use Class 3.1
- EMC standards emission :Cisco ASR 9006 is designed to meet: · FCC Class 47CFR15 A · ICES 003 Class A · AS/NZS CISRP22 Class A · CISPR 22 (EN55022) Class A · VCCI Class A · BSMI Class A · IEC/EN 61000-3-12: Power Line Harmonics · IEC/EN 61000-3-11: Voltage Fluctuations and Flicker · EN55022: Information Technology Equipment (Emissions) · EN 50121-4: Railway EMC
- EMC standards immunity :Cisco ASR 9006 is designed to meet: · IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) · IEC/EN-61000-4-3: Radiated Immunity (10V/m) · IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) · IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM) · IEC/EN-61000-4-5: Signal Surge Ports (1kV) · IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM) · IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms) · IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) · IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations · EN55024: Information Technology Equipment (Immunity) · EN50082-1/EN-61000-6-1: Generic Immunity Standard · EN 50121-4: Railway EMC
- Safety :Cisco ASR 9006 is designed to meet: · UL/CSA/IEC/EN 60950-1 · IEC/EN 60825 Laser Safety · ACA TS001 · AS/NZS 60950 · FDA Code of Federal Regulations Laser Safety