null

Cisco A9K-MOD80-SE 2x Open Expansion Module Slot (Service Edge) Line Card

(No reviews yet) Write a Review
MPN:
A9K-MOD80-SE
Condition:
Refurbished
Shipping:
Calculated at Checkout
$1,199.00
Frequently bought together:

Description

A9K-MOD80-SE-ref Overview

A9K-MOD80-SE is Cisco ASR 9000 Mod80 Modular Line Card, Service Edge Optimized, requires modular port adapters. Cisco ASR 9000 Series modular line cards provide customers with a flexible solution supporting multiple combinations of Ethernet ports, all in a single slot of the Cisco ASR 9000 Series Aggregation Services Routers. Modular line cards support a wide range of interfaces and densities.

Quick spec of A9K-MOD80-SE-ref

  • Product Number : A9K-MOD80-SE
  • Type : ASR 9000 Mod80 Modular Line Card, Service Edge Optimized, requires modular port adapters
  • Physical Dimensions : 14.5 W x 1.72 H x 22.40 L 14.5 W x 1.72 H x 24.25 L (including ejector levers)
  • Weight : 17.5 lbs. (est.) (7.93 Kg)
  • Chassis compatibility : Compatible with the Cisco ASR 9922, 9010, 9006 and 9001 systems
  • Port density : Up to 2 modular port adapters are supported per line card.

A9K-MOD80-SE-ref Specification

  • Type :ASR 9000 Mod80 Modular Line Card, Service Edge Optimized, requires modular port adapters
  • Physical Dimensions :14.5 W x 1.72 H x 22.40 L 14.5 W x 1.72 H x 24.25 L (including ejector levers)
  • Weight :17.5 lbs. (est.) (7.93 Kg)
  • Chassis compatibility :Compatible with the Cisco ASR 9922, 9010, 9006 and 9001 systems
  • Port density :Up to 2 modular port adapters are supported per line card.
  • Ethernet :· IEEE 802.3 compliant · 10 Gigabit Ethernet PHY monitoring · IEEE 802.x flow control · Full-duplex operation · Per-port byte and packet counters for policy drops; oversubscription drops; cyclic redundancy check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets
  • Card density :Maximum number of line cards per system: Cisco ASR 9922 = 20, Cisco ASR 9010 = 8, and Cisco ASR 9006 = 4
  • Options :Each line card is available as either a Service Edge Optimized (enhanced QoS) or Packet Transport Optimized (basic QoS) line card.
  • Reliability and availability :Line card online insertion and removal (OIR) support without system impact
  • Network Equipment Building Standards (NEBS) :Cisco ASR 9000 Series Routers are designed to meet: · SR-3580: NEBS Criteria Levels (Level 3) · GR-1089-CORE: NEBS EMC and Safety · GR-63-CORE: NEBS Physical Protection
  • Operating temperature (nominal) :41 to 104ºF (5 to 40ºC)
  • Operating temperature (short-term) :23 to 131ºF (–5 to 55ºC)
  • Operating humidity (nominal) relative humidity :10 to 85%
  • Storage temperature :–40 to 158ºF (–40 to 70ºC)
  • Storage relative humidity :5 to 95% Note: Not to exceed 0.024 kg of water per kg of dry air
  • Operating altitude :–60 to 4000m (up to 2000m conforms to IEC, EN, UL, and CSA 60950 requirements)
  • ETSI standards :Cisco ASR 9000 Series Routers are designed to meet: · EN300 386: Telecommunications Network Equipment (EMC) · ETSI 300 019 Storage Class 1.1 · ETSI 300 019 Transportation Class 2.3 · ETSI 300 019 Stationary Use Class 3.1 · EN55022: Information Technology Equipment (Emissions) · EN55024: Information Technology Equipment (Immunity) · EN50082-1/EN-61000-6-1: Generic Immunity Standard
  • EMC standards :Cisco ASR 9000 Series Routers are designed to meet: · FCC Class A · ICES 003 Class A · AS/NZS 3548 Class A · CISPR 22 (EN55022) Class A · VCCI Class A · BSMI Class A · IEC/EN 61000-3-2: Power Line Harmonics · IEC/EN 61000-3-3: Voltage Fluctuations and Flicker
  • Immunity :Cisco ASR 9000 Series Routers are designed to meet: · IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) · IEC/EN-61000-4-3: Radiated Immunity (10V/m) · IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) · IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM) · IEC/EN-61000-4-5: Signal Ports (1kV) · IEC/EN-61000-4-5: Surge DC Port (1kV) · IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms) · IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) · IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
  • Safety :Cisco ASR 9000 Series Routers are designed to meet: · UL/CSA/IEC/EN 60950-1 · IEC/EN 60825 Laser Safety · ACA TS001 · AS/NZS 60950 · FDA: Code of Federal Regulations Laser Safety
View AllClose

Contact

Warranty:
365 days
CALL:
877-263-8436
E-MAIL:
sales@networkgenetics.net